Configuring arrays on hp smart array controllers reference guide part number 433572006 june 2010 sixth edition. Some software requires a valid warranty, current hewlett packard. You are in the range where the controller isnt even working to do anything. Install firmware for the hp p410i storage controller in. Software cd or web software cd or web preinstalled in rom of hp smart array controllers when the utility can be used. In 16bay systems there is usually a p410 along with a p410i controller. Hardwareassisted sas raid uses the lsi megaraid driver already present in the linux. Hp p410i raid controller terrible sequential write.
When the controller displays press to run the option rom configuration for arrays utility, press f8. Hardwareassisted raid is a step up from software raid, but is not considered true hardware raid. The low profile, halfheight card has 8 ports and utilizes ddr2800 memory. I entered configuration utility for the raid controller hp smart array p410i and removed all logical drives, as there is no need for a hardware raid if youre going to use zfs. I wanted to keep an eye on the hdds, so i needed to install a utility that can monitor and interact with the raid controller.
To configure an array on an hp smart array controller, three utilities are available. Find answers to hard drive failure on hp smart array p410i from the expert community at experts exchange. I installed an hp p410 raid controller in my hp n40l proliant microserver. Installing and configuring sas hardware raid on hp workstations. I have just installed windows 10 on a seperate partition of my hard drive so i have both operating systems currently. Hdds will be visible to operating system only as logical devices after they are configured in controller. The overall impression regarding building storage system on hp proliant dl380 g7 is miserable. Hp smart array p410i controller raid configuration. Smart array controllers and smart host bus adapters hpe.
Hp smart array p410i1g with fbwc storage controller raid sata 1. Hp smart array controllers for hp proliant servers user guide part number 469988005 february 2010 fifth edition. If the raid controller presents one drive to the os, that is what the os will see. Theres no raid setup utility when the system boots. I have a hp elitebook 8570w that was shipped with windows 7. The hp array configuration utility is a webbased application that helps you configure hp. Also, any suggestions on how to determine if the p410i is a bottleneck would be helpful. Software raid todays operating systems offer basic support for raid disks called software raid to create and manage logical drives that do not contain the os. Product bulletin, research or buy hp printers, desktops, laptops, servers, storage, enterprise solutions and more at the official hewlettpackard website.
It provides enterpriseclass storage performance, and increased scalability and data protection to hpe synergy compute modules. You cant just toss some consumer drives into the server and expect them to work. Hi all, i cannot find the right driver for the raid controller. My unit has the 256mb cache on it and i would love to get raid 6 enabled. Do you users of hp p410i raid controllers as found in the dl380g6 know if one can mix and match sata arrays with sas ones. Hp smart array p410i controller raid configuration it blog ixnfo. Hp p410i raid controller does not like ssd drives lowendtalk. Open the firmware storage controller and download the supplemental update.
The lsi 3041e is a 4port satasas raid controller providing sas support for the hp xw4000 and. You arent in the ballpark of the controller being the bottleneck. Installing a license key with array configuration utility acu. Hp ml350 g6 smart array p410i controller raid 5 1 array 1 logical drive 6 tb drive configuration. Hp smart array p420i controller storage controller raid sata 6gbs sas 6gbs pcie 3. Hewlett packard enterprise hpe smart array p420i raid. Configuring arrays on hp smart array controllers reference. Hp proliant integrated smart array controllers, and hp proliant storageworks raid array controllers. I cannot configure the raid on my p410i, and the only reason i can imagine. Hp smart array p410i1g with fbwc storage controller. I have ran some disk benchmarks on this drives and i get mbps read and only 10mbps write speeds. Hp protectsguards against that by restricting thirdparty drive use in their servers. Hardware installed remotely and it is difficult to reach noc every week to check drives status. So i just recently acquired an hp dl360 g7 with an integrated p410i raid controller.
Hp smart array p410i controller raid configuration youtube. Hp proliant smart array controllers, hp proliant integrated smart array controllers, and hp proliant storageworks raid array controllers. The controller is running well in a parallel installation of windows server 2016 on the same hw and in the old w10 1703. But i see no way of getting notification of a drive failure other than having to manually open the hp array configuration utility software yourself.
I checked the bios and it shows the raid controller as the primary boot device. Hp p410 raid smart array controller card anandtech. This is for the hardware guys, i have installed an ssd drive to a p410i raid controller and the io is awful does not gets more than 61mbs where this should be around 500mbs, i have changed a lot of settings on the controller, disable cache and nothing makes any difference. The hp smart array p410i raid controller is not compatible with every ssd. Hp smart array p410i controller hp proliant dl 360 365 raid hp smart array p410i. Aug 02, 2015 hp dl360 g7 p410i controller troubleshooting up vote1down vote favorite.
The low profile, half height card has 8 ports and utilizes ddr2800 memory. Discussion in servers and enterprise solutions started by lixxus, nov 16, 2015. Software raid is just one option out of many on freenas, just as zfs is only an option there. The official hp software page for the information below is here. Im working on a z840 workstation with a windows server 2016 6544588. However as its laid out, best of luck getting up and running quickly if you follow that page.
I have 4 drives to setup as a raid 5 configuration but cannot figure out how to do this. Hp smart array controllers for hp proliant servers user guide. This driver provides support for the hp smart array b110i sata raid controller on microsoft windows server 2012 and microsoft windows server 2012 r2. Hp smart array p420i controller storage controller raid. Although the only difference i can see is that the p411 has its two sas connectors external and it supports a maximum of 100 drives to the p410s maximum support for 24 drives. Install firmware for the hp p410i storage controller using.
I have a an hp dl380 g7 server with a hp smart array p410i raid card. At any rate you should be able to manage the array with the software within windows. We purchased an hp ml350 g6 server with a p410i raid controller. The hpe smart array p420i controller is a low profile, 6 gbs, pcie 3. Hp smart array p410 raid controller management server. You can use the array configuration utility for several tasks such as configuring. If you do not press any key, you will be given a chance to run the option rom. The product literature says you can but im looking for realworld. Six 6 available pciexpress gen 2 expansion slots standard with optional pcixpcix express or x16 risers. The server boots and i can start up linux mint from usb, but when i tried to install it to a hard drive, machine reported no drives found. Hp dl360p gen8 p420i controller ixsystems community. Hp p410i raid controller, mix and match sata and sas.
You can use the array configuration utility for several. Is there supposed to be a license number that needs to be added to make the card work. I have attached a single 2tb sata samsung hard drive and created a raid 0 array with the single drive. I was trying to install nas4free freebsd on a hp proliant dl380g7. Hp p410 raid controller and ssd oletho oct 15, 20 8.
Hp proliant smart array embedded sata raid controller driver. Slow drive speeds with hp smart array p410i servethehome. Smart array p212, p410, p410i, p411, p711m, p712m, and p812. As you have a hardware raid controller youd be mad to just use it for jbod, only to then raid the disks in software. The smart array controller moves the data from the cache to the drams, verifies that the data is correct, and then transfers it to the disk drives. The drives have not failed, but they definitely are not meant to be used with that controller. Hp smart array p410 raid controller stops working after. Hard drive failure on hp smart array p410i solutions. Hp 451792001 512mb batery backed write cache bbwc module ddr2533mhz, 72bit wide for hp smart array p410i and p700m controllers hp hp smart array p410256mb controller. Hp proliant bl460c g7 64bit blade server with 2xsixcore. Installing and configuring sas hardware raid on hp. Hp 462919001 smart array p410 sas controller newegg.
If i remember correctly the hp sas expander card is only officially supported with the p410 and p410i raid controllers though, not the p411 you mentioned. Hpe ssa replaces the existing hp array configuration utility, or acu, with an. Hp proliant bl460c g7 64bit blade server with 2xsixcore x5675 xeon 3. The option rom messages will go through each raid controller installed on the system. I have a question about hp p410 raid smart array controller card. Hp smart array p410256mb controller storage controller raid sata150 sas low profile 300 mbps raid 0, 1, 5, 10, 50 pci express x8 smart array p410256mb pcie2 int only manufacturer part number 462862b21.
Raid 10 uses effectively no controller overhead, so the controller is idle. The hp array configuration utility is a webbased application that helps you configure hp proliant smart2 array controllers, hp proliant smart array controllers, hp proliant integrated smart array controllers, and hp proliant storageworks raid array controllers. Hp smart array p410 controller hewlett packard enterprise. Linux hp smart array raid controller sumguys ramblings.
50 371 1047 1299 832 164 1449 878 587 750 672 816 214 622 1564 510 1330 336 1455 1380 477 161 1444 1065 1144 1291 1149 537 675 337 776 760 1414 102